Cable Construction :

* Conductor     Plain Annealed Copper wire class 2 according to IEC 60228
* Insulation     Extruded XLPE ( Crosslinked Polyethylene )
* Individual Screen    Helically Overlapped Polyester Tape
Tinned Annealed Copper Wire 0.5 mm2 ( 20/0.18 mm )
Helically Overlapped Single coated Aluminium Tape contacted with drain wire
Helically Overlapped Polyester Tape
* Overall Screen   Helically Overlapped Polyester Tape
Tinned Annealed Copper Wire 0.5 mm2 ( 20/0.18 mm )
Helically Overlapped Single coated Aluminium Tape contacted with drain wire
Helically Overlapped Polyester Tape
* Inner Sheath    Extruded PVC Flame Retardant ( Black )
* Armour    Galvanized Steel Wire
* Outer Sheath    Extruded PVC Flame Retardant ( Black or requested by customer )
Pair Identification :    
* 1 Pair     Black and White
* Multi Pair   Black and White with numbering
Amount of halogen acid gas   Max. 17% ( IEC 60754-1)
Limiting oxigen index ( LOI )   Min 30% ( IEC 60332-3 annex B )
Sunlight resistance   UL 1581 section 1200
Oil resistance   ICEA S-82-552
Flame Retardant   IEC 60332-1
Flame Propagation   IEC 60332-3 cat. A, B, C
Nominal Voltage   300 V dan 500 V
Insul Resistance     Min. 1000 MOhm/km
Test Voltage   300 V : 1000 V/1 min
500 V : 2000 V/1 min
Screen Resistance   Min 1 MOhm/km
Min.Bending Radius     6 x OD ( fixed installation )
Temperature Rating   -40° C to 70° C
Symbol  : CU/XLPE/IS-OS/SWA/PVC or P1 T2 IS-OS
Applicable Standard   Multipair XLPE Insulated Instrumentation Cable
Flame Retardant, UV Resistant
According to BS EN 50288-7 : 2005
Voltage Designation 300 V & 500 V
P1 T2 IS-OS   XLPE Insulated, Individual and Overall Collective Screen, Armoured
Other Specification are available on request
Application   Suitable for connecting instrument and control system for analogue or digital signal transmission.These cables shall not be connected directly to mains electricity supply or other low impedance sources and not designed to be used for power supply.Suitable for direct buried applications.